A pre-burial downspout and yard-drain checklist for approved discharge location, pipe type and size, inlet adapters, cleanouts, slope, bedding, joints, solid versus perforated pipe, foundation and utility clearance, freeze and surcharge risk, daylight or storm connection, erosion protection, tracer or route records, and testing before soil hides the system.

6 items to check

Inspection progress0 of 6
0%

Discharge route and outlet are approved and do not harm the building or neighboring property

Critical item

Roof water should reach an allowed location without foundation return, erosion, nuisance flow, or prohibited sewer connection.

Pipe material, diameter, solid or perforated sections, fittings, and cleanouts match the drainage plan

Critical item

The system should convey roof water and remain maintainable.

Slope, bedding, support, alignment, and frost or traffic conditions are addressed

Critical item

Buried pipe should drain or function as designed without bellies, crushing, or settlement.

Downspout adapters, joints, basins, and wall penetrations are secure and watertight where intended

Critical item

Connections should not disconnect, leak against the foundation, or admit excessive debris.

Controlled flow reaches the outlet without backup, leakage, or unexplained standing water

Critical item

The installed route should be tested before burial when safe and permitted.

Route, depth, cleanouts, outlet, initial cover, and restoration responsibilities are documented

The owner should be able to locate and service the buried system.

Use after buried roof-drain piping is installed but before trench backfill, landscaping, or hardscape conceals it. Stormwater discharge rules and allowed connections vary locally. Do not use unsafe ladders, walk roofs, remove structural support, or disturb lead, asbestos, or mold-containing assemblies. Require qualified building-envelope, structural, roofing, window, door, and siding professionals where appropriate.

Reference standards

  • Approved wall, window, door, roof, deck, siding, drainage, and structural details; adopted state and local building and energy code; permit and inspection conditions; authority having jurisdiction requirements; signed scope; and exact flashing, membrane, sealant, fastener, cladding, window, door, and drainage manufacturer instructions
  • Approved site-drainage plan, stormwater or utility requirements, pipe, fitting, inlet, cleanout, emitter, and backfill instructions
  • Tools

  • Approved drawings, opening and product submittals, wall-section details, permit records, and authorized changes
  • Tape measure, level, flashlight, camera, and owner-safe ground-level observations
  • Dated pre-cover photographs and manufacturer-compatible material records showing drainage-plane continuity