5 items to check

Inspection progress0 of 5
0%

Reinforcing layout matches the approved structural design

Critical item

Bar size, spacing, direction, layers, beam reinforcement, steps, benches, walls, floor, transitions, and locally reinforced zones should match the sealed or approved design.

Steel is securely supported with required separation from soil and forms

Critical item

Concrete or shotcrete cover, bar support, stability, and separation from earth should follow the approved structural design and accepted supports for the exposure and placement method.

Splices, bends, congestion, and steel condition are acceptable

Critical item

Lap locations and lengths, mechanical splices, bends, hooks, bar condition, and congestion should follow the structural details and placement requirements.

Drains, returns, lights, niches, skimmers, sleeves, and waterstops are coordinated

Critical item

Embedded pool components and penetrations should be listed or approved, securely positioned, compatible with the shell system, and reinforced or detailed as required by the design.

Required inspections and full photo record are complete before placement

Critical item

Do not place shotcrete or gunite until required structural, electrical bonding, plumbing, and permit inspections are approved and corrections are documented.

Use this checklist after reinforcing steel and embedded items are substantially complete but before shotcrete or gunite. The approved structural design and required inspection govern bar size, spacing, laps, cover, and special details.

Reference standards

  • Approved plans, contract documents, adopted state and local codes, permit conditions, authority having jurisdiction requirements, and manufacturer installation instructions
  • Approved structural pool drawings, engineering details, and inspection requirements
  • Reinforcing steel, supports, embedded items, shotcrete or gunite, and pool-system specifications
  • Approved electrical bonding and plumbing plans for interfaces visible before shell placement
  • Tools

  • Approved structural drawings and revisions
  • Camera, tape measure, cover or spacing tools used by qualified inspectors, and inspection records
  • Product information for embedded fittings, waterstops, sleeves, and shell penetrations