5 items to check

Inspection progress0 of 5
0%

Every pool line is identified and matches the approved hydraulic plan

Critical item

Pipe size, material, route, suction or return function, drains, skimmers, spa, water features, cleaner, fill, overflow, and equipment connections should match the approved design.

Joints, supports, penetrations, and protection are ready for testing

Critical item

Pipe cutting, preparation, solvent welding or joining, cure time, supports, sleeves, bedding, separation, and protection should follow the pipe system and approved plans.

Test method, isolation, gauge, and acceptance criteria are documented

Critical item

The responsible qualified party should define the safe test medium, pressure, duration, temperature considerations, isolation method, gauge range, and acceptance criteria under local requirements and manufacturer instructions.

All accessible joints and readings remain stable through the required test

Critical item

A passing test should meet the approved acceptance criteria without leakage, unexplained pressure loss, fitting movement, or unsafe test conditions.

Passing record and protection plan remain in place until concealment

Critical item

Test results, photos, inspection approval, repairs, retests, line labels, and protection should remain traceable through shell, backfill, deck, and equipment construction.

Use this checklist after pool piping is installed and supported but before the shell, backfill, decking, or equipment work hides critical joints and routes. The approved hydraulic design, local code, test procedure, and pipe-system instructions control the test medium, pressure, duration, and acceptance.

Reference standards

  • Approved plans, contract documents, adopted state and local codes, permit conditions, authority having jurisdiction requirements, and manufacturer installation instructions
  • Approved pool hydraulic, plumbing, equipment, and suction-outlet plans
  • Pipe, fitting, solvent cement, valve, pressure-test, equipment, and embedded fitting manufacturer instructions
  • Required permit inspection and pressure-test documentation
  • Tools

  • Approved piping plan and line identification
  • Calibrated test equipment selected by qualified personnel, camera, and test log
  • Access to every visible joint, valve, fitting, penetration, and gauge connection