Adecuación estructural
Punto críticoCómo verificar
1. Check floor joist size — ceiling joists (typically 2x6) are NOT adequate for living space loads
2. Measure ceiling height — minimum 7 feet over at least 50% of the required floor area
3. Check that no roof structural members (collar ties, ridge beams) have been cut or modified without engineering
4. Verify load path — additional floor load must transfer down to the foundation
5. Look for sagging or bouncing when walking across the floor
6. Check if a structural engineer has evaluated the conversion
7. Verify knee walls are properly built and braced
Problemas frecuentes
- Ceiling joists used as floor joists without reinforcement (joists designed for 10 PSF ceiling load vs 40 PSF floor load)
- Collar ties or rafters cut to gain headroom (compromises roof structure)
- No structural engineering review
- Floor bounces when walked on
- Knee walls not properly braced
- Foundation not evaluated for additional load