Instalación de revestimiento
Punto críticoCómo verificar
1. Check that panels are loose — should slide 1/4" side to side (thermal expansion requirement)
2. Verify nails are centered in nail slots and not driven tight (1/32" gap between nail head and siding)
3. Check panel overlap — minimum 1" at horizontal joints
4. Verify panels are level — sight along the bottom edges
5. Check J-channel around windows and doors — properly flashed behind
6. Verify starter strip is level at the bottom
7. Check corner posts are plumb and properly overlapping
8. Look for buckling or waviness (indicates nails driven too tight)
Problemas frecuentes
- Nails driven tight (siding buckles in heat — most common vinyl siding problem)
- Insufficient overlap at joints
- J-channel not properly flashed (water enters behind)
- Wavy panels from improper nailing
- Starter strip not level
- Panels cut too tight at ends (can't expand)