Tapajuntas y sello climático
Punto críticoCómo verificar
1. Check flashing kit — should be manufacturer-specific for the skylight model
2. Verify step flashing on sides is woven with shingles (not just surface-applied)
3. Check head (top) flashing extends under shingles above
4. Check sill (bottom) flashing directs water over shingles below
5. Verify no exposed sealant or caulk as primary weather seal (should be mechanical flashing)
6. Check from inside attic — any daylight visible around the frame? (leak path)
7. After rain: check for water stains around the skylight from inside
Problemas frecuentes
- Generic flashing instead of manufacturer kit (poor fit, guaranteed leaks)
- Step flashing not woven with shingles (water runs behind)
- Head flashing not extending under upper shingles
- Sealant used as primary waterproofing (fails within 3-5 years)
- Improper sill flashing (water backs up under skylight)
- Visible water stains around skylight on ceiling