Skip to content

Surge Protection Inspection

Checklist for inspecting whole-house and point-of-use surge protection per REBT ITC-BT-23 / UNE-EN 61643-11 and REBT ITC-BT-18.

6 items to check

BETA

These checklists are in development and testing. Information is for reference only and does not replace professional consultation. Data may contain inaccuracies. Consult a qualified professional.

If you notice an error, please email [email protected].

Inspection progress0 of 6
0%

Risk assessment

Per REBT ITC-BT-23 / UNE-EN 61643-11, surge protection requirements should be based on a risk assessment considering: lightning flash density in the area, utility power reliability, presence of sensitive electronic equipment, and the value of equipment to be protected. Higher-risk installations require more comprehensive protection.

Type 1/Type 2 SPD at service entrance

Critical item

Per REBT ITC-BT-23 / UNE-EN 61643-11 and REBT ITC-BT-17, a whole-house surge protective device (SPD) should be installed at the main service panel. The SPD must be rated Type 1 or Type 2 with a minimum surge current rating of 50 kA (per mode). Installation must use short, straight conductor runs (maximum 25 cm / 10 inches lead length).

Type 3 point-of-use protection

Per REBT ITC-BT-23 / UNE-EN 61643-11, Type 3 point-of-use surge protectors provide the final layer of protection at sensitive equipment. For critical electronics, an uninterruptible power supply (UPS) with surge protection provides both surge protection and battery backup. Plug-in SPDs should be listed and have adequate joule ratings.

Grounding system verification

Critical item

Per REBT ITC-BT-18, surge protection effectiveness depends entirely on the quality of the grounding system. Ground rod resistance should be 10 ohms or less. All grounding electrodes must be bonded together, and the grounding electrode conductor must be continuous without splices.

Data line protection

Per REBT ITC-BT-23 / UNE-EN 61643-11 and REBT ITC-BT-36 / UNE-EN 50174, surge protection should extend to all conductive paths entering the building: coaxial cable (TV/internet), Ethernet cables, and telephone lines. Each service entrance point should have appropriate surge protection installed.

Testing and maintenance

Per REBT ITC-BT-23 / UNE-EN 61643-11 and manufacturer specifications, surge protection devices must be regularly inspected and tested. SPDs should be checked after any known surge event (lightning strike, power outage). Failed SPDs must be replaced immediately as they provide no protection after failure.

Checklist for inspecting whole-house and point-of-use surge protection per REBT ITC-BT-23 / UNE-EN 61643-11 and REBT ITC-BT-18.

Reference Standards

  • REBT — REBT
  • REBT ITC-BT-23 / UNE-EN 61643-11 — Surge protective device standards
  • REBT ITC-BT-18 — Grounding and bonding requirements
  • Tools Needed

  • Multimeter
  • Ground resistance tester
  • Non-contact voltage tester
  • Outlet tester (3-light or digital)
  • Clamp meter
  • Insulation resistance tester
  • Flashlight