Thermal Insulation and Energy Efficiency

Checklist for inspecting thermal insulation and energy efficiency in accordance with the EPBD (Energy Performance of Buildings Directive), EN standards and CTE DB HE.

3 items to check

BETA

These checklists are in development and testing. Information is for reference only and does not replace professional consultation. Data may contain inaccuracies. Consult a qualified professional.

If you notice an error, please email [email protected].

Inspection progress0 of 3
0%

Wall Insulation

Critical item

In accordance with the EPBD and national energy efficiency regulations, external walls must achieve the required U-value (typically 0.15-0.30 W/m2K for new buildings, varying by climate zone). Insulation products must comply with EN 13162-EN 13171. Continuous insulation must minimise thermal bridges per EN ISO 10211. CTE DB HE 1 establishes thermal transmittance limit values for each climate zone in Spain.

Roof and Floor Insulation

Critical item

In accordance with the EPBD, roofs typically require U-values of 0.10-0.20 W/m2K and ground floors 0.15-0.25 W/m2K (varying by climate and national regulations). Vapour barriers must be placed on the warm side of the insulation per EN ISO 13788 to prevent interstitial condensation. CTE DB HE 1 establishes specific requirements for each climate zone in Spain.

Airtightness and Ventilation

Critical item

In accordance with the EPBD and EN 13829, building airtightness must be verified by pressurisation test (blower door). Typical requirement: air change rate <=3.0 h-1 at 50 Pa (n50) for new buildings, <=0.6 h-1 for passive houses. Controlled ventilation must be provided per EN 15251 to ensure indoor air quality while maintaining energy efficiency. CTE DB HE 1 and CTE DB HS 3 establish airtightness and ventilation requirements for buildings in Spain.

Checklist for inspecting thermal insulation and energy efficiency in accordance with the EPBD (Energy Performance of Buildings Directive), EN standards and CTE DB HE.

Reference Standards

  • EPBD (EU Directive 2010/31/EU, recast 2024) — Energy Performance of Buildings
  • EN ISO 6946 — Thermal resistance of building components
  • EN 13162-EN 13171 — Thermal insulation products
  • EN 13829 — Air permeability of buildings (pressurisation test)
  • CTE DB HE — Basic Document on Energy Saving
  • Required Tools

  • Thermal imaging camera (infrared)
  • U-value (thermal transmittance) meter
  • Blower door for airtightness testing
  • Tape measure and thickness gauge